Reliable jointing of Flexijoint waterstops can be carried out rapidly on site with a heater blade. An electric heater blade is available and provide for all Flexijoint waterstops series.
When jointing,
- Make sure that ends of the Flexijoint waterstops to be jointed are of the same width and profile, clean them with water or a non oily solvent;
- Cut both ends off square with a sharp knife;
- Place the Flexijoint waterstops side by side against the heater blade and press until it is melt without burning or charring;
- Removed the heater blade with an upward movement;
- Quickly joint the molten ends together;
- Hold the Flexijoint waterstops together firmly for approximately 20 seconds to allow the molten Flexijoint waterstops fuse completely;
- Switch off the heater blade;
- While the heater blade is still hot, clean thoroughly with a wire brush and ready for the next joint.
Flexijoint waterstops installation accessories, Heater Blade market and sale by Flexijoint Industrial Marketing & Services, Kuala Lumpur, Malaysia.
For further enquiry of this product, please call +6 016 3111313 or email : flexijoint.ims@gmail.com.